2015 Quantum® Controller Manual

Circuit Breaker Card

The Circuit Breaker Card provides overload and short-circuit protection for the three major circuits contained on the Dryer Control Panel.

  1. CCB or Control Circuit Breaker for the 120vac components;
  2. RCB or Remote Circuit Breaker for the QUANTUM® Monitor;
  3. QCB or QUANTUM® Circuit Breaker for the Slave CPU.

Overload conditions are protected by means of resettable circuit breakers, while an instantaneous short circuit is protected by means of a replaceable fuse. The entire assembly is built with a "pluggable" connector for easy field replacement. The assembly is located on the lower right-hand side of the I/O Carrier Board. The Circuit Breaker Card should be one of the first things checked when the Dryer Panel is dead.

1

2

3

Copyright © 2014-2016 CTB, Inc. All rights reserved                                                                                                                                                                                                                   BLV0216