IMPORTANT! Natural Gas piping must be Schedule 40 black iron pipe or stronger, connected to the fitting on natural gas Dryers.

For proper operation, at least 8 psi [55.2 kPa] must be supplied. Use maximum line size when natural gas pressure is 8-10 psi [55.2 - 68.9 kPa]. Table values apply on natural gas downstream of the gas company meter and Regulator only. Contact the gas company for greater equivalent lengths than shown in the Chart. If available natural gas pressure is higher than 20 psi [137.9 kPa], a primary Regulator must be provided to reduce the Dryer inlet pressure to 10-20 psi [68.9 - 137.9 kPa].