SQ08-SQ40 General Safety

4. Shut off the fuel supply valve closest to the fire and at the Tank (if LP is used). Turn the Gas Hand Shutoff Valve at a 90-degree angle to the Lower Plumbing Train to CLOSE.

3. Shut off power from the Provider’s incoming lines at the Service Disconnect so there is NO POWER AT ALL coming to the Dryer.


I important for all Operators to know the location of, and obey safety warnings regarding the power Service Provider’s Service Disconnect, sometimes in a building away from the Dryer. The Service Disconnect is provided by the Owner.

 

2. Pull DOWN the Dryer DISCONNECT Handle on the inner door of the Dryer Disconnect Box.

 

This shuts off electrical current to the Dryer Control Panel and trips the main breaker. Remember: Doing this does NOT yet shut off the Electrical Power Cabinet’s INCOMING power from the outside electrical Service Provider.

1. Press the RED EMERGENCY STOP Button on the red Control Panel to shut down the Dryer immediately.

 

This stops the Fans to eliminate air supply to the fire. Remember: Doing this does NOT yet shut off the incoming power from the Electrical Power Cabinet to the Control Panel.

In the event of a Dryer FIRE,
act immediately!

 

ACT IMMEDIATELY if there are gas FUMES or unusual noises or vibrations. 
ACT IMMEDIATELY at the FIRST APPEARANCE of smoke or smolder.

 

In the event of a FIRE, CALL 9-1-1 IMMEDIATELY

Follow applicable procedures for such an emergency.

Below: Take Step 1 or Step 2 FIRST, whichever Control you are closest to.  Within a minimum 15 seconds between, shut off power at the other control:

SQ-D Model

CONTINUED >

Copyright © 2014-2016 CTB, Inc. All rights reserved  BL0815