Proper Fuel Line Connection is Critical
IMPORTANT! Connect the Plumbing lines only to fuel lines specified.
A Fuel WARNING Plate (5537-00049 or 5537-00050) is located on or near the connection hose or pipe. See below. See also SAFETY Manual Main Menu. Review specific approved fuels see links below.
Fuel Warning Plate (LP Only) 5537-00050
Fuel Warning Plate (Nat Gas) 5537-00049
LP Dryers must have one SHUTOFF VALVE at each tank, and should have another valve within 5' - 25' [1 524 - 7 620] of the Dryer. All valves must be easily accessible.
Natural-gas Dryers must have a MANUAL SHUTOFF VALVE installed in the supply line at least 25’ [7 620] from the Dryer and easily accessible.
All Dryers must have a proper EXCESS FLOW valve —in the LP fuel line at the tank—sized according to fuel line size.
Combo Dryers
Combo Dryers are shipped with LP Orifices installed. Burner Orifices need to changed when switching fuel types. Natural Orifices are shipped loose with Combo Dryers.
Before Initial Startup
Check the complete plumbing system for leaks or tightness of fittings, especially at unions. Use a liquid soap solution with the plumbing train under normal operating pressure. Purge new plumbing lines before final assembly to blow oil, dirt, and thread chips out of the lines that could interfere with proper operation and damage plumbing components.
GO TO LP Fuel
GO TO Natural Gas Fuel
Copyright © 2014-2016 CTB, Inc. All rights reserved BL0815